The Problem

The same 6 m office beam as the shear worked example: 300 × 600 mm, C30/37, B500B, carrying g_k = 35 kN/m and q_k = 20 kN/m. The design moment is 347.6 kNm at midspan, and the shear post took 4H25 as the main steel from a “bending pre-step” it did not show. This post is that step. The task is to design the longitudinal steel for bending at the ultimate limit state: solve the neutral axis from the rectangular stress block, size the bars, verify the provided section against the design moment, and check whether the steel yields before the concrete crushes — every intermediate value shown. No iteration is needed: the equilibrium equation is a quadratic, and both roots should be examined.

The Relevant Clauses

  • §6.1(2): plane sections remain plane; tensile strength of the concrete is ignored; concrete stresses from §3.1.7 and steel stresses from §3.2
  • §3.1.6(1)P, Eq (3.15): f_cd = α_cc · f_ck / γ_C — α_cc = 1.0 is the recommended value (0.8–1.0; check your National Annex)
  • §3.1.7(3), Eq (3.19) and (3.20): rectangular stress block with λ = 0.8 and η = 1.0 for f_ck ≤ 50 MPa
  • Table 3.1: C30/37 — f_ctm = 2.9 MPa, ε_cu3 = 3.5 ‰ (bilinear diagram, Figure 3.4)
  • §3.2.7(2) and (4): f_yd = f_yk / γ_S, E_s = 200 GPa
  • §9.2.1.1(1), Eq (9.1N) and §9.2.1.1(3): minimum and maximum longitudinal steel
  • §8.2(2): minimum clear spacing between bars
  • EN 1990 Eq (6.10): persistent design situation, γ_G = 1.35, γ_Q = 1.5
  • §5.5(4), Eq (5.10a): neutral-axis limit for linear analysis with limited redistribution — δ ≥ k₁ + k₂·x_u/d, with recommended k₁ = 0.44 and k₂ = 1.25(0.6 + 0.0014/ε_cu2); at δ = 1 this gives x_u/d ≤ 0.45 for C50/60

All values below are the EN 1992-1-1 recommended (CEN) values. Check your National Annex before relying on any of them.

Input Data

Parameter Value Unit Notes
Span L 6,000 mm Simply supported
b 300 mm Beam width
h 600 mm Overall depth
g_k 35 kN/m Permanent, incl. self-weight
q_k 20 kN/m Office + movable partitions
f_ck 30 MPa C30/37
f_yk 500 MPa B500B
c_nom 35 mm XC1, structural class S4 (as post #1)
Links H8 mm Two legs
Main bars 4H25 — To be confirmed in Step 6
Max aggregate d_g 20 mm For the spacing check

Step-by-Step Calculation

Step 1: Material Properties

Concrete design strength, §3.1.6(1)P Eq (3.15):

f_cd = α_cc × f_ck / γ_C = 1.0 × 30 / 1.5 = 20.0 MPa

Steel design strength, §3.2.7(2):

f_yd = f_yk / γ_S = 500 / 1.15 = 434.8 MPa

Design yield strain, §3.2.7(4) with E_s = 200 GPa:

ε_yd = f_yd / E_s = 434.8 / 200,000 = 0.002174 (2.174 ‰)

From §3.1.7(3) for f_ck ≤ 50 MPa: λ = 0.8, η = 1.0. From Table 3.1, C30/37: ε_cu3 = 3.5 ‰, f_ctm = 2.9 MPa. The ε_cu3 = 3.5 ‰ limit belongs to the bilinear diagram of Figure 3.4; combined with the rectangular block of §3.1.7(3) (Figure 3.5) it is the standard ULS idealisation used in this post.

Step 2: Design Moment

Load combination, EN 1990 Eq (6.10):

w_d = 1.35 × 35 + 1.5 × 20 = 47.25 + 30.0 = 77.25 kN/m

M_Ed = w_d × L² / 8 = 77.25 × 6.0² / 8 = 347.6 kNm

Step 3: Effective Depth

d = h − c_nom − φ_link − φ_main/2 = 600 − 35 − 8 − 25/2 = 544.5 mm

The cover is inherited from the shear post: exposure class XC1 with structural class S4 gives c_nom = 35 mm under §4.4.1 and the National Annex. If your cover step gives a different value, d moves and every number below changes.

Step 4: Neutral Axis from Equilibrium

The rectangular block (§3.1.7(3), Figure 3.5) gives the concrete force:

C = η × f_cd × b × λx = 1.0 × 20 × 300 × 0.8x = 4,800x (N, x in mm)

The lever arm between C and the steel is:

z = d − λx/2 = 544.5 − 0.4x

The resistance is M = C × z:

M(x) = 4,800x × (544.5 − 0.4x)

Setting M(x) = M_Ed = 347.6 × 10⁶ N·mm gives a quadratic:

0.4x² − 544.5x + 72,421.9 = 0

x = [544.5 ± √(544.5² − 4 × 0.4 × 72,421.9)] / (2 × 0.4)

x = [544.5 ± √(296,480 − 115,875)] / 0.8 = [544.5 ± 425.0] / 0.8

The two roots are x = 149.4 mm and x = 1,211.8 mm. The second root is not a section: 0.8x would be 969 mm, deeper than the 600 mm beam. Only the first root is valid. This is worth doing explicitly — the invalid root is how a negative or nonsense lever arm slips into a spreadsheet.

At x = 149.4 mm:

x/d = 149.4 / 544.5 = 0.274

z = 544.5 − 0.4 × 149.4 = 484.7 mm

Step 5: Required Reinforcement

Equilibrium of forces, C = T:

C = 4,800 × 149.4 = 717,139 N = 717.1 kN

A_s,req = C / f_yd = 717,139 / 434.8 = 1,649 mm²

Step 6: Bar Selection

Option A_s (mm²) M_Rd (kNm) Utilisation Verdict
3H25 1,473 314.5 1.11 ✗
4H20 1,257 272.6 1.28 ✗
4H25 1,963.5 404.1 0.86 ✓
3H32 2,413 479.5 0.72 ✓

3H25 lands at a utilisation of 1.11 — 11 % short, the most common result of sizing off A_s,req alone and rounding to a familiar pattern. I keep 4H25, the same steel as the shear post, so the series works one beam rather than four. 3H32 also passes on area; it fails nothing here, but larger bars make anchorage and crack control harder in a 300 mm web, so the redundant option buys nothing.

Step 7: Verify the Provided Section

For 4H25, A_s = 4 × 490.9 = 1,963.5 mm². The steel force at yield:

T = A_s × f_yd = 1,963.5 × 434.8 = 853.7 kN

The neutral axis follows from C = T:

x = T / (η × f_cd × b × λ) = 853,693 / (1.0 × 20 × 300 × 0.8) = 177.9 mm

z = 544.5 − 0.4 × 177.9 = 473.4 mm

M_Rd = T × z = 853.7 × 473.4 / 1,000 = 404.1 kNm

Utilisation: M_Ed / M_Rd = 347.6 / 404.1 = 0.86.

The steel strain at the design section, from strain compatibility (§6.1(2)):

ε_s = ε_cu3 × (d − x) / x = 3.5 × (544.5 − 177.9) / 177.9 = 7.22 ‰

That is more than three times ε_yd = 2.174 ‰, so the steel yields well before the concrete crushes. Good — but “the steel yields” is a conclusion, and Step 8 shows how to prove it before choosing bars rather than after.

Step 8: The Balanced Section — When Does the Steel Yield?

The balanced section is the one where the concrete reaches ε_cu3 and the steel reaches ε_yd at the same instant. Strain compatibility gives:

x_bal / d = ε_cu3 / (ε_cu3 + ε_yd) = 3.5 / (3.5 + 2.174) = 0.617

For this section:

x_bal = 0.617 × 544.5 = 335.9 mm

z_bal = 544.5 − 0.4 × 335.9 = 410.1 mm

M_bal = η × f_cd × b × λx_bal × z_bal = 20 × 300 × 0.8 × 335.9 × 410.1 / 10⁶ = 661.2 kNm

A_s,bal = M_bal / (f_yd × z_bal) = 661.2 × 10⁶ / (434.8 × 410.1) = 3,708 mm² (ρ = 2.06 % of A_c)

The demand is M_Ed / M_bal = 347.6 / 661.2 = 0.53. Below 1 means the required steel is less than A_s,bal, so the steel yields before the concrete crushes — the section is under-reinforced. If M_Ed had exceeded M_bal, any steel quantity that satisfied moment would leave the steel below yield, and the section would need compression reinforcement or a larger depth.

The balanced point is a property of the section, not a code limit: it tells you when the steel yields, not whether the section is admissible. The limit on a singly reinforced section comes from §5.5(4), Eq (5.10a), which ties the neutral-axis depth to the redistribution δ used in the analysis:

δ ≥ k₁ + k₂ · x_u/d

with k₁ = 0.44 and k₂ = 1.25(0.6 + 0.0014/ε_cu2) at the recommended values. For no redistribution (δ = 1) and ε_cu2 = 3.5 ‰, k₂ = 1.25 and the expression gives x_u/d ≤ 0.448 — the familiar 0.45 limit is this equation evaluated at δ = 1, not a separate ductility rule. The Designer’s Guide to EN 1992-1-1 (§5.2.1) reads clause 5.5 the same way and sets the singly reinforced limit from it: when the moment exceeds the limiting value for the δ used, the section needs compression reinforcement (§5.2.2, Eqs D5.7/D5.8), not more tension steel.

For this beam, x/d = 0.327 at the provided steel, below 0.448, so a singly reinforced section is admissible and 4H25 is the whole solution. The balanced ratio of 0.617 sits well above both — that margin is what makes the yielding conclusion comfortable.

Step 9: Detailing Checks

Minimum steel, §9.2.1.1(1) Eq (9.1N):

A_s,min = max(0.26 × f_ctm / f_yk, 0.0013) × b × d = max(0.26 × 2.9 / 500, 0.0013) × 300 × 544.5

= max(0.001508, 0.0013) × 163,350 = 246 mm² ✓

Maximum steel, §9.2.1.1(3): A_s,max = 0.04 × A_c = 0.04 × 180,000 = 7,200 mm² ✓

Reinforcement ratio: ρ = 1,963.5 / 180,000 = 1.09 %.

Clear spacing, §8.2(2):

s_clear = (300 − 2 × 35 − 2 × 8 − 4 × 25) / 3 = 38 mm

The minimum is max(k₁φ, d_g + 5, 20) = max(25, 25, 20) = 25 mm with 20 mm aggregate, so 38 mm passes. With 32 mm aggregate the limit becomes 37 mm and the check still passes, barely.

Result Summary

Check Value Reference Ratio Result
M_Rd 404.1 kNm M_Ed = 347.6 kNm 0.86 ✅
A_s required 1,649 mm² 1,963.5 mm² (4H25) 0.84 ✅
A_s,min (§9.2.1.1(1)) 1,963.5 mm² 246 mm² 0.13 ✅
A_s,max (§9.2.1.1(3)) 1,963.5 mm² 7,200 mm² 0.27 ✅
x/d provided 0.327 balanced 0.617 0.53 ✅
ε_s at M_Ed 7.22 ‰ ε_yd = 2.174 ‰ 3.3 ✅
Clear bar spacing (§8.2(2)) 38 mm 25 mm 0.66 ✅

The provided x/d in the table is 177.9 / 544.5 = 0.327; the required one is 0.274. Both sit well below the balanced ratio of 0.617, which is the point of Step 8.

What This Post Does Not Cover

Shear design and crack width have their own worked examples in this series; deflection, anchorage and curtailment, flanged (T-) sections, doubly reinforced sections, and continuous beams with redistribution are outside this example. The design is for a persistent load case on a simply supported beam; seismic detailing and accidental combinations are not addressed.

The Download

📥 Download the full calculation spreadsheet

The workbook carries every value in this post — inputs, the quadratic, the balanced-section check, the bar options and the detailing checks — as values only. It is free, no email gate. If something in it does not reconcile with your own calculation, email me at hugo@civion.cloud and I will look at it.

What I’m Building

Bending design is where most spreadsheet errors enter a project: a wrong lever arm or an unchecked second root is invisible in the output and decisive in the design. I’m building Civion’s EC2 RC Column Section Designer to run this equilibrium — and the strain-compatibility check behind it — across load cases at once, with every intermediate value kept visible. If that sounds useful, write to me at hugo@civion.cloud and I’ll tell you when it’s ready.